• English
    • Türkçe
  • English 
    • English
    • Türkçe
  • Login
View Item 
  •   DSpace Home
  • Akademik Arşiv / Institutional Repository
  • Mühendislik Fakültesi / Faculty of Engineering
  • İnşaat Mühendisliği Bölümü / Department of Civil Engineering
  • View Item
  •   DSpace Home
  • Akademik Arşiv / Institutional Repository
  • Mühendislik Fakültesi / Faculty of Engineering
  • İnşaat Mühendisliği Bölümü / Department of Civil Engineering
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Performance of mechanical steel bar splices using grouted couplers under uniaxial tension

Thumbnail
Date
2021
Author
Ghayeb, Haider Hamad
Razak, Hashim Abdul
Sulong, N. H. Ramli
Mo, Kim Hung
Abutaha, Fuad
Gordan, Meisam
Metadata
Show full item record
Abstract
In this study, grouted couplers were used to connect steel bars as an alternative approach to the conventional steel bar lapping method. The aim is to avoid bar congestion problems and to reduce the required quantity of steel bars in order to achieve the development length in practice. Two categories of couplers, i.e., short-threaded grout coupler and long grout coupler, in nine groups as well as one group of deformed bars, were tested under uniaxial tension. In total, 30 samples (including three repeated samples in each group) were tested. The examined parameters were types of couplers, embedded bar length, and bar eccentricity. For the short-threaded grout couplers, the embedded bar length, which is equivalent to 8 times bar diameter with bar eccentricity equal to zero, exhibited the best performance in terms of strength, ductility, energy absorption, and failure mode, which is suitable to be used in the high seismic zone. Additionally, the short-threaded grout couplers with the embedded bar length equal to 7 times bar diameter and the long grout couplers that required embedded bar length that is equal to 8 times bar diameter, are suitable to be used in the low-to-medium seismic zone. Besides, the embedded bar length that is smaller than or equal to the 6 times bar diameter was not sufficient to be utilised in the short-threaded grout couplers and long grout couplers to resist the seismic load due to inadequate bar embedded length. Also, the predicted model is sufficient to estimate the ultimate tensile strength of the grouted couplers.
URI
http://hdl.handle.net/20.500.12566/898
Collections
  • İnşaat Mühendisliği Bölümü / Department of Civil Engineering
  • Scopus İndeksli Yayınlar Koleksiyonu
  • WOS İndeksli Yayınlar Koleksiyonu

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 




sherpa/romeo


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeABU AuthorWOSScopusPubMedTRDizinErişimThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeABU AuthorWOSScopusPubMedTRDizinErişim

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


|| Library || Antalya Bilim Üniversitesi || OAI-PMH ||

Antalya Bilim Üniversitesi Kütüphane ve Dokümantasyon Müdürlüğü, Antalya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: acikerisim@antalya.edu.tr

DSpace Repository:


DSpace 6.4-SNAPSHOT

Gemini Bilgi Teknolojileri A.Ş tarafından destek verilmektedir.