• English
    • Türkçe
  • Türkçe 
    • English
    • Türkçe
  • Giriş
Öğe Göster 
  •   E-arşiv Ana Sayfası
  • Akademik Arşiv / Institutional Repository
  • Sağlık Hizmetleri Meslek Yüksekokulu / Vocational School of Health Services
  • Tıbbi Görüntüleme Teknikleri Programı / Medical Imaging Techniques Program
  • Öğe Göster
  •   E-arşiv Ana Sayfası
  • Akademik Arşiv / Institutional Repository
  • Sağlık Hizmetleri Meslek Yüksekokulu / Vocational School of Health Services
  • Tıbbi Görüntüleme Teknikleri Programı / Medical Imaging Techniques Program
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Mamografi sistemlerinde ilgi alanı türev ve ince gruplama seçimlerinin modülasyon transfer fonksiyonunun üzerine etkileri

Thumbnail
Göster/Aç
Mamografi sistemlerinde ilgi alanı türev ve ince gruplama seçimlerinin modülasyon transfer fonksiyonunun üzerine etkileri (732.0Kb)
Tarih
2020
Yazar
Üncü, Yiğit Ali
Özdoğan, Hasan
Üst veri
Tüm öğe kaydını göster
Özet
Bu çalışmada, mamografi sisteminin görüntü kalitesi matematiksel yöntemler ile ölçülmüştür. Mamografi sistemlerinde performans ölçümleri için uygulanan yeni yöntemler, bu sistemlerin görüntü kalitesinin sayısal olarak değerlendirilmesinde kullanılmıştır. Görüntüleme kalitesinin sayısal değerlendirilmesi, görsel değerlendirmelere göre daha objektif sonuçlar verdiğinden çalışma kapsamında sayısal değerlendirmeler üzerinde durulmuştur. Modülasyon transfer fonksiyonu (MTF) hesaplanmasında kenar görüntüleme metodu kullanılmış ve bu metodun kullanımında açı hesaplamaları yapılmıştır. Farklı ilgi alan seçimlerinde (ROI) kenar dağılım fonksiyonlarının (ESF) nasıl değiştiği gözlemlenmiş, farklı türev seçimlerinin çizgisel dağılım fonksiyonu (LSF) ve MTF üzerine etkisi ve ince gruplama (rebinning) işleminin ESF, LSF, MTF üzerine etkileri incelenmiştir. Bütün bu yöntemlerin hesaplamaları, MATLAB programı kullanılarak tasarlanıp gerçekleştirilmiştir.
 
In this study, the image quality of the mammography system was measured by mathematical methods. New methods for performance measurements have been used to quantitatively evaluate the image quality in mammography systems. Since the quantitative evaluation of imaging quality gives more objective results than evaluation of visual, numerical evaluations have been emphasized within the scope of the study. The Slanted-edge method was used for the calculation of modulation transfer function (MTF), and angular calculations were made in the use of this method. On effect of different region-of-interest (ROI) selection on edge spread function (ESF), use of different differentiation methods for line spread function (LSF), MTF, and on the effect of different rebinning sizes on ESF, LSF and MTF were investigated. All these methods consist of the calculation were designed to perform using the MATLAB program.
 
Bağlantı
http://hdl.handle.net/20.500.12566/573
Koleksiyonlar
  • Tıbbi Görüntüleme Teknikleri Programı / Medical Imaging Techniques Program

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 




sherpa/romeo


Göz at

Tüm E-arşivBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreABU Yazarına GöreWOSScopusPubMedTRDizinErişimBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreABU Yazarına GöreWOSScopusPubMedTRDizinErişim

Hesabım

GirişKayıt

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


|| Kütüphane || Antalya Bilim Üniversitesi || OAI-PMH ||

Antalya Bilim Üniversitesi Kütüphane ve Dokümantasyon Müdürlüğü, Antalya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: acikerisim@antalya.edu.tr

E-arşiv@AntalyaBilim:


DSpace 6.4-SNAPSHOT

Gemini Bilgi Teknolojileri A.Ş tarafından destek verilmektedir.