Seismic retrofit of full-scale substandard extended rectangular RC columns through CFRP jacketing: test results and design recommendations

Thumbnail
Date
2019
Author
Farrokh Ghatte, Hamid
Comert, Mustafa
Demir, Cem
Akbaba, Mustafa
Ilki, Alper
Metadata
Show full item record
Abstract
Brittle behavior of substandard columns during earthquakes is among the most common reasons of structural failures. Because capacity design principles and ductile detailing concepts have not been properly adopted during the construction of a large portion of existing buildings, many of them require seismic retrofitting. Among other deficiencies, lack of sufficient ductility is generally the major problem. External fiber-reinforced polymer (FRP) jacketing of columns is a feasible and promising method to overcome the problem of insufficient column ductility in existing substandard buildings. However, experimental data on the behavior of full-scale substandard columns is scarce, particularly in the case of columns with extended rectangular cross sections. Consequently, current standards do not allow FRP jacketing for the enhancement of ductility against seismic actions when the cross-sectional aspect ratio is higher than 1.5. Therefore, in this study, the seismic performance of full-scale substandard columns with extended rectangular cross sections is investigated both experimentally and theoretically. The columns are tested before or after retrofitting with carbon fiber-reinforced polymer (CFRP) jacketing. The findings of the study clearly demonstrate the efficiency of FRP jacketing for substandard columns, even for the case of extended rectangular cross sections. Furthermore, nonlinear analyses of reference and FRP-retrofitted columns, and comparison of the results of analytical study with experimental data, revealed that FRP retrofit design methods recommended by the American Concrete Institute (ACI) and Turkish codes are quite conservative, leading to unfeasible retrofit options, whereas the Eurocode approach leads to more realistic and economical retrofit solutions.
URI
http://hdl.handle.net/20.500.12566/443
Collections
  • İnşaat Mühendisliği Bölümü / Department of Civil Engineering

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 




sherpa/romeo


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeABU AuthorWOSScopusPubMedTRDizinErişimThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeABU AuthorWOSScopusPubMedTRDizinErişim

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


|| Library || Antalya Bilim Üniversitesi || OAI-PMH ||

Antalya Bilim Üniversitesi Kütüphane ve Dokümantasyon Müdürlüğü, Antalya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: acikerisim@antalya.edu.tr

DSpace Repository:


DSpace 6.4-SNAPSHOT

Gemini Bilgi Teknolojileri A.Ş tarafından destek verilmektedir.