• English
    • Türkçe
  • English 
    • English
    • Türkçe
  • Login
View Item 
  •   DSpace Home
  • Akademik Arşiv / Institutional Repository
  • Sağlık Hizmetleri Meslek Yüksekokulu / Vocational School of Health Services
  • Tıbbi Görüntüleme Teknikleri Programı / Medical Imaging Techniques Program
  • View Item
  •   DSpace Home
  • Akademik Arşiv / Institutional Repository
  • Sağlık Hizmetleri Meslek Yüksekokulu / Vocational School of Health Services
  • Tıbbi Görüntüleme Teknikleri Programı / Medical Imaging Techniques Program
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effects of deuteron optical model potentials on the production cross-section calculations of 66-68Ga 66 - 68Ga from natZn and natGe

Thumbnail
Date
2022
Author
Şekerci, Mert
Özdoğan, Hasan
Kaplan, Abdullah
Metadata
Show full item record
Abstract
Since it was reported that several radioisotopes might be advantageous for different medical uses in diagnostics and therapeutics, they have gained significance. Theoretical and experimental researches on such radioisotopes have contributed to the literature on a wide variety of topics, including production route research, getting activation and yield values, optimum production method analysis, clinical effects and production cross-section calculations. This study was motivated by the studies described in this domain as well as those published in the literature. The primary purpose of this study is to investigate the effects of deuteron optical model potentials in various reactions where 66-68Ga radioisotopes, which are known to be medically important, have been generated with deuteron induced particles on natZn and natGe targets. The experimental data from the literature and the calculation results generated using the five deuteron optical model potentials accessible in the TALYS code (version 1.95) were compared in line with the objective of this study. The experimental results in the literature and the data obtained as an outcome of the computations are graphically illustrated in order to comprehend these comparisons. Furthermore, to perform a numerical assessment, mean weighted deviation and relative variance calculations were also performed.
URI
http://hdl.handle.net/20.500.12566/1313
Collections
  • Tıbbi Görüntüleme Teknikleri Programı / Medical Imaging Techniques Program

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 




sherpa/romeo


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeABU AuthorWOSScopusPubMedTRDizinErişimThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeABU AuthorWOSScopusPubMedTRDizinErişim

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


|| Library || Antalya Bilim Üniversitesi || OAI-PMH ||

Antalya Bilim Üniversitesi Kütüphane ve Dokümantasyon Müdürlüğü, Antalya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: acikerisim@antalya.edu.tr

DSpace Repository:


DSpace 6.4-SNAPSHOT

Gemini Bilgi Teknolojileri A.Ş tarafından destek verilmektedir.