Basit öğe kaydını göster

dc.contributor.authorGhayeb, Haider Hamad
dc.contributor.authorRazak, Hashim Abdul
dc.contributor.authorSulong, N. H. Ramli
dc.contributor.authorMo, Kim Hung
dc.contributor.authorAbutaha, Fuad
dc.contributor.authorGordan, Meisam
dc.date.accessioned2021-10-01T07:40:00Z
dc.date.available2021-10-01T07:40:00Z
dc.date.issued2021
dc.identifier.citationGhayeb, H. H., Razak, H. A., Sulong, N. H. R., Mo, K. H., Abutaha, F. & Gordan, M. (2021). Performance of mechanical steel bar splices using grouted couplers under uniaxial tension. Journal of Building Engineering, 34.en_US
dc.identifier.issn2352-7102
dc.identifier.urihttp://hdl.handle.net/20.500.12566/898
dc.description.abstractIn this study, grouted couplers were used to connect steel bars as an alternative approach to the conventional steel bar lapping method. The aim is to avoid bar congestion problems and to reduce the required quantity of steel bars in order to achieve the development length in practice. Two categories of couplers, i.e., short-threaded grout coupler and long grout coupler, in nine groups as well as one group of deformed bars, were tested under uniaxial tension. In total, 30 samples (including three repeated samples in each group) were tested. The examined parameters were types of couplers, embedded bar length, and bar eccentricity. For the short-threaded grout couplers, the embedded bar length, which is equivalent to 8 times bar diameter with bar eccentricity equal to zero, exhibited the best performance in terms of strength, ductility, energy absorption, and failure mode, which is suitable to be used in the high seismic zone. Additionally, the short-threaded grout couplers with the embedded bar length equal to 7 times bar diameter and the long grout couplers that required embedded bar length that is equal to 8 times bar diameter, are suitable to be used in the low-to-medium seismic zone. Besides, the embedded bar length that is smaller than or equal to the 6 times bar diameter was not sufficient to be utilised in the short-threaded grout couplers and long grout couplers to resist the seismic load due to inadequate bar embedded length. Also, the predicted model is sufficient to estimate the ultimate tensile strength of the grouted couplers.en_US
dc.description.sponsorshipNo sponsoren_US
dc.language.isoengen_US
dc.publisherJournal of Building Engineeringen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBond-slip failureen_US
dc.subjectBağ kayma hatasıtr_TR
dc.subjectFracture failureen_US
dc.subjectKırık hatasıtr_TR
dc.subjectGrouted couplersen_US
dc.subjectDerzli kaplinlertr_TR
dc.subjectMechanical spliceen_US
dc.subjectMekanik eklemetr_TR
dc.subjectPrecast connectoren_US
dc.subjectPrekast bağlayıcıtr_TR
dc.subjectUniaxial tensile testen_US
dc.subjectTek eksenli çekme testitr_TR
dc.titlePerformance of mechanical steel bar splices using grouted couplers under uniaxial tensionen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.relation.publicationcategoryInternational publicationen_US
dc.identifier.wosWOS:000608432300005
dc.identifier.scopus2-s2.0-85097657195
dc.identifier.volume34
dc.contributor.orcid0000-0001-8748-6207 [Abutaha, Fuad]
dc.contributor.abuauthorAbutaha, Fuad
dc.contributor.yokid301450 [Abutaha, Fuad]
dc.contributor.ScopusAuthorID57160193100 [Abutaha, Fuad]
dc.identifier.doi10.1016/j.jobe.2020.101892