Basit öğe kaydını göster

dc.contributor.authorBeyaz, Mustafa İlker
dc.date.accessioned2022-04-04T12:40:51Z
dc.date.available2022-04-04T12:40:51Z
dc.date.issued2021
dc.identifier.citationBeyaz, M. İ. (2021). An acoustic blood pressure sensing scheme using time of flight and shear wave elastography techniques. Sensors and Actuators A-Physical, 330(112865).en_US
dc.identifier.issn0924-4247
dc.identifier.urihttp://hdl.handle.net/20.500.12566/1093
dc.description.abstractA novel wearable blood pressure sensor scheme is presented. The design incorporates an array of piezoelectric transducers to transmit acoustic waves through the skin, and receive reflected echoes from an arterial wall. The novelty ofthe device lies in the arrangement and operation ofthe transducers that allow for the application oftime of flight and shear wave elastography techniques to detectthe artery expansion and Young’s Modulus, respectively. The detection of these two parameters are imperative for a reliable blood pressure measurement insensitive to potential physiological changes in the body or the artery tissue. Finite element analysis was used to simulate the acoustic time of flight, shear wave propagation, and mechanical expansion of the artery wall. The device operation was experimentally validated using off-the-shelf components prior to device fabrication. The acoustic time of flight was shown to change with pressure in a decreasing linear trend. In addition, the peaks and valleys of an artificially-generated shear wave as well as the direction of wave propagation were shown to be detected. The results clearly demonstrate the capability of this design to determine the expansion and the mechanical properties of an artery. Further implementation of the device will enable the development of reliable and accurate wearable BP sensors for continuous monitoring of hypo- and hypertension-related diseases.en_US
dc.description.sponsorshipNo sponsoren_US
dc.language.isoengen_US
dc.publisherSensors and Actuators A-Physicalen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPressure sensoren_US
dc.subjectBasınç sensörütr_TR
dc.subjectBlood pressureen_US
dc.subjectKan basıncıen_US
dc.subjectPiezoelectric transduceren_US
dc.subjectPiezoelektrik dönüştürücütr_TR
dc.subjectTime of flighten_US
dc.subjectUçuş sürecitr_TR
dc.subjectShear wave elastographyen_US
dc.subjectKayma dalgası elastografisitr_TR
dc.subjectMEMSen_US
dc.titleAn acoustic blood pressure sensing scheme using time of flight and shear wave elastography techniquesen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.relation.publicationcategoryInternational publicationen_US
dc.identifier.wosWOS:000672578200010
dc.identifier.scopus2-s2.0-85107619128
dc.contributor.orcid0000-0003-4591-2882 [Beyaz, Mustafa İlker]
dc.contributor.abuauthorBeyaz, Mustafa İlker
dc.contributor.yokid107317 [Beyaz, Mustafa İlker]
dc.contributor.ScopusAuthorID24343068300 [Beyaz, Mustafa İlker]
dc.identifier.doi10.1016/j.sna.2021.112865


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster